• EI
  • Scopus
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
  • DOAJ
  • EBSCO
  • 北大核心期刊
  • 中国核心学术期刊RCCSE
  • JST China
  • FSTA
  • 中国精品科技期刊
  • 中国农业核心期刊
  • CA
  • WJCI
  • 中国科技核心期刊CSTPCD
  • 中国生物医学SinoMed
中国精品科技期刊2020
张权, 沙比拉·吐拉江, 周贻兵, 林野, 李磊, 刘利亚, 刘文政, 吴玉田, 郭华. 不同种类固相萃取柱测定韭菜中58种农药残留量的净化效果比较[J]. 食品工业科技, 2019, 40(20): 243-250,261. DOI: 10.13386/j.issn1002-0306.2019.20.039
引用本文: 张权, 沙比拉·吐拉江, 周贻兵, 林野, 李磊, 刘利亚, 刘文政, 吴玉田, 郭华. 不同种类固相萃取柱测定韭菜中58种农药残留量的净化效果比较[J]. 食品工业科技, 2019, 40(20): 243-250,261. DOI: 10.13386/j.issn1002-0306.2019.20.039
ZHANG Quan, SHABILA Tu-la-jiang, ZHOU Yi-bing, LIN Ye, LI Lei, LIU Li-ya, LIU Wen-zheng, WU Yu-tian, GUO Hua. Comparison of Purfication Effect of Different Types of SPE Column on the Dertermination of 58 Pesticide Residues in Chives[J]. Science and Technology of Food Industry, 2019, 40(20): 243-250,261. DOI: 10.13386/j.issn1002-0306.2019.20.039
Citation: ZHANG Quan, SHABILA Tu-la-jiang, ZHOU Yi-bing, LIN Ye, LI Lei, LIU Li-ya, LIU Wen-zheng, WU Yu-tian, GUO Hua. Comparison of Purfication Effect of Different Types of SPE Column on the Dertermination of 58 Pesticide Residues in Chives[J]. Science and Technology of Food Industry, 2019, 40(20): 243-250,261. DOI: 10.13386/j.issn1002-0306.2019.20.039

不同种类固相萃取柱测定韭菜中58种农药残留量的净化效果比较

Comparison of Purfication Effect of Different Types of SPE Column on the Dertermination of 58 Pesticide Residues in Chives

  • 摘要: 在比较不同种类的固相萃取柱净化效果上优化了前处理条件,建立了韭菜基质中58种农药残留的气相色谱-质谱法(GC/MS)检测方法。试样经乙腈提取,采用石墨化炭黑/氨基柱(PC/NH2)净化后,用GC/MS选择离子监测扫描模式(SIM)进行检测,基质匹配溶液外标法定量。结果表明,目标物在65.2~1043.0 ng/mL范围内呈良好的线性相关,相关系数(r)均不小于0.990,方法的检出限(LOD,S/N=3)为0.001~0.007 mg/kg,定量限(LOQ,S/N=10)为0.003~0.024 mg/kg。分别在韭菜基质中做低、中、高3个添加水平的加标回收试验,该方法的平均回收率为62.2%~125.2%,相对标准偏差RSD(n=3)在0.5%~9.5%之间。该方法样品处理简单快速,相比QuEChERS的净化效果要好,灵敏度和选择性高,适用于韭菜复杂基质中多组分农药的筛查确证和定量分析。

     

    Abstract: To optimize pretreatment conditions in comparing the purification effects of different types of solid phase extraction columns,a gas chromatography-mass spectrometry(GC/MS)method was established for the determination of 58 pesticide residues in chives.The samples were extracted by acetonitrile,cleaned-up with Cleanert PC/NH2 solid-phase extractant,and determined by GC/MS using matrix-matched external standard method. The determination coefficients(R2)of all the 58 pesticides in the range of 65.2~1043.0 ng/mL were not less than 0.990. The limits of detection(LODs)were 0.001~0.007 mg/kg when signal/noise was 3(S/N=3). The limits of quantification(LOQs)were 0.003~0.024 mg/kg(S/N=10).For recovery test,there were three levels(low,medium and high)spiked in chives. The average recoveries of the method were 62.2%~125.2% and the relative standard deviations(RSDs,n=3)were 0.5%~9.5%. Compared with QuEChERS method,the method has the advantages of simple and rapid processing,high purification sensitivity and selectivity which is suitable for screening and quantitative analysis of multi-component pesticides in the chives matrix.

     

/

返回文章
返回