• EI
  • Scopus
  • 食品科学与工程领域高质量科技期刊分级目录第一方阵T1
  • DOAJ
  • EBSCO
  • 北大核心期刊
  • 中国核心学术期刊RCCSE
  • JST China
  • FSTA
  • 中国精品科技期刊
  • 中国农业核心期刊
  • CA
  • WJCI
  • 中国科技核心期刊CSTPCD
  • 中国生物医学SinoMed
中国精品科技期刊2020
徐阳鑫,高雪,孙敏君,等. 粘菌素功能化的Fe3O4-GQDs作为荧光探针用于快速检测大肠杆菌[J]. 食品工业科技,2021,42(11):9−14. doi: 10.13386/j.issn1002-0306.2020070027.
引用本文: 徐阳鑫,高雪,孙敏君,等. 粘菌素功能化的Fe3O4-GQDs作为荧光探针用于快速检测大肠杆菌[J]. 食品工业科技,2021,42(11):9−14. doi: 10.13386/j.issn1002-0306.2020070027.
XU Yangxin, GAO Xue, SUN Minjun, et al. Colistin-functionalized Fe3O4-GQDs as a Fluorescent Probe for Rapid Detection of Escherichia coli [J]. Science and Technology of Food Industry, 2021, 42(11): 9−14. (in Chinese with English abstract). doi: 10.13386/ j.issn1002-0306.2020070027.
Citation: XU Yangxin, GAO Xue, SUN Minjun, et al. Colistin-functionalized Fe3O4-GQDs as a Fluorescent Probe for Rapid Detection of Escherichia coli [J]. Science and Technology of Food Industry, 2021, 42(11): 9−14. (in Chinese with English abstract). doi: 10.13386/ j.issn1002-0306.2020070027.

粘菌素功能化的Fe3O4-GQDs作为荧光探针用于快速检测大肠杆菌

Colistin-functionalized Fe3O4-GQDs as a Fluorescent Probe for Rapid Detection of Escherichia coli

  • 摘要: 目的:建立一种通过粘菌素功能化的Fe3O4-石墨烯量子点(Colis-Fe3O4-GQDs)荧光探针检测革兰氏阴性细菌-大肠杆菌(Escherichia coli)浓度的分析方法。方法:通过共沉淀法制备了氨基修饰的Fe3O4,并将其与含羧基的石墨烯量子点(GQDs)结合,并用粘菌素修饰形成Colis-Fe3O4-GQDs复合物,以此复合物作为荧光探针对不同浓度的大肠杆菌进行检测。结果:大肠杆菌对Colis-Fe3O4-GQDs复合物荧光猝灭效果良好,并且随着菌株浓度的不断增加,其对Colis-Fe3O4-GQDs复合物的荧光猝灭逐渐增强。此方法的检测线性范围为1×102~10×102 CFU/mL,决定系数为0.999,检测限为0.36×102 CFU/mL。结论:该Colis-Fe3O4-GQDs生物传感器检测方法简单、高效,具有良好的选择性和灵敏度,为革兰氏阴性菌检测提供了新的方法,在细菌检测方面具有广阔的应用前景。

     

    Abstract: Objective: To establish a method for the determination of Gram-negative bacteria - Escherichia coli by Colis-Fe3O4-graphene quantum dots (GQDs) functionalized fluorescent probes. Methods: Amino modified Fe3O4 was prepared by co-precipitation method, and it was combined with GQDs containing carboxyl groups, and Colis-Fe3O4-GQDs complex was formed by colistin modification. With this complex as fluorescent probe, different concentrations of Escherichia coli were detected. Results: The fluorescence quenching effect of Colis-Fe3O4-GQDs complex was good with Escherichia coli, and the fluorescence quenching of Colis-Fe3O4-GQDs complex was gradually enhanced with the increasing concentration of the strain. The linear detection range of this method was 1×102~10×102 CFU/mL, the coefficient of determination was 0.999, and the detection limit was 0.36×102 CFU/mL. Conclusion: The colis-Fe3O4-GQDs biosensor is simple and efficient, with good selectivity and sensitivity, which provides a new method for the detection of Gram-negative bacteria, and has a broad application prospect in the detection of bacteria.

     

/

返回文章
返回